Deprecated: Creation of dynamic property cls_session::$session_data_table is deprecated in /www/sites/www.188bio.com/index/systems/cls_session.php on line 49
IQ Products/Complete standardized high quality kit for the diagnosis of HIT/IQP-396188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

IQ Products/Complete standardized high quality kit for the diagnosis of HIT/IQP-396

Information

IntroductionHeparin-inducedthrombocytopenia(HIT)isanacute,immune-mediatedprocessthatmayresultinlife-threateningthrombosis.HITiscausedbyplatelet-activating,heparin-dependentantibodies,whoformcomplexesofheparintogetherwitheitherplateletfactor-4(PF-4)(mostoftheclinicalcases),interleukin-8(IL-8)orneutrophil-activatingpeptide2(NAP-2).Detectionoftheseantibodiesisanimportantlaboratoryfunction.

Theantibodiesareinitiallyformedafter5ormoredayswhenapatienthasbeenonheparintherapy.Animmuneresponsetoaheparindosemaybeobservedwithinminutesorhoursifthepatienthashadpreviousexposuretoheparinandantibodiesarealreadycirculating.

ThediagnosisofHITisdifficultbecauseitssignsarenon-specificandduetotheabovementionedstructureitisveryimportanttolookforthepresenceandfunctionofthecomplexspecificantibodies.

DiagnosticsFordetectionofHITtwodifferentkindofassayscanbeused,theimmunologicalandfunctionalassay.Thefunctionalassaysreproducethein-vivopathophysiology,andhighlycorrelatewiththeclinicalpresentationofHIT.Thisisincontrasttotheimmune-detectionantigen(antigenemia)assays,whichmeasureantibodiesreactivetotheheparinplatelet-factor4(PF4)complexes.However,onlyafractionofpatientspositiveinthesetestsdevelopclinicalHIT.Ontheotherhand,pathogenicantibodiesmayalsoreactwithotherheparincomplexes,suchasheparin-interleukin-8,orheparin-neutrophilactivatingpeptide2,thus,notbeingdetectedbythoseassays.

AnimmunologicalassaycanbetheEnzyme-LinkedImmunosorbentAssay(ELISA)ortheGelTest(PaGIA),whichissimilartoELISA.Thedisadvantageofthesetestsisthefactthattheyarenon-functionalassays,theygivemorethan10%falsenegativeanda20%disagreementwithSRA.

AfunctionalassayistheSEROtonin-releaseassay(SRA),whichissensitiveandspecific, butnon-feasIBLebecauseoftheuseofrADIoisotypes.AnotherfunctionalassayistheAggregationAssaybutithasalowsensitivityandalongtimetoperform.

PrincipleoftheHITAlert™KitRecently,theAmericanCollegeofChestPhysicians(ACCP)haspostedupdatesonrecommendationsfortestingofHIT.ThisshouldfurtherincreasetheneedofhighperformancetestingforHIT.TheHITAlert™Kitissuchatest.

FortheHITAlert™Kitdonorplatelets(PRP)areused,whichareincubatedinthepresenceofpatientserumandinthepresenceorabsenceofheparin.WhenpathogenicantibodiesarepresenttheactivationofthedonorplateletsisshownusingaplateletactivationMarker.Byincubatingthesampleswithanantibodyagainstplateletsandtheactivationmarkerthisreactioncanbevisualizedusingflowcytometry.

Results

ABC
PE positive platelets - HITAlert™ KitNegative patient - HITAlert™ KitPositive patient - HITAlert™ Kit

Figure:ResultsofHITAlert™Kit:(A)dotplotofPEpositiveplatelets,(B)negativepatient,(C)positivepatient.

新闻动态
行业前沿
技术文章
最新产品