Deprecated: Creation of dynamic property cls_session::$session_data_table is deprecated in /www/sites/www.188bio.com/index/systems/cls_session.php on line 49
Altogen/293 Transfection Reagent (Emb Kidney, CRL-1573)/8.0 ml/7014188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

Altogen/293 Transfection Reagent (Emb Kidney, CRL-1573)/8.0 ml/7014

Description

Product Availability: In Stock (delivery within 2-3 business days, no extra charge for drop-shipping).

Ordering: To place an order via credit card or PO use Add to Cart button (creating an account is not required).


Transfection Reagent for 293 Cells (Embryonic Kidney Cells, CRL-1573)

  • Two component formulation enhances lipid mediated transfection efficiency
  • Optimized easy-to-use transfection protocol provided for transfection of siRNA, DNA, mRNA, and microRNA
  • Kit includes Transfection Enhancer reagent and recommended transfection protocol
  • High transfection efficacy in the presence of serum
  • Expand your RNAi application with a reagent optimized for delivery of both siRNA and plasmid
  • Reproducible transfection results
  • Works well for standard reverse transfection and high-throughput applications
  • Download in vitro 293 transfection protocol: [PDF]
  • Download 293 CRISPR/Cas9 transfection protocol: [PDF]
  • Download PowerPoint presentation for 293 cells transfection kit: [PPT]
  • Developed and manufactured by Altogen Biosystems

Transfection Efficiency:
Reagent exhibits at least 90% transfection efficiency of siRNA delivery. Transfection efficiency was determined by real-time RT-PCR.

Transfection Protocol and MSDS:
Download Altogen Biosystems 293 Transfection Protocol: [PDF]
Download MSDS: [PDF]

293 Cell Line:
The 293 cell line was established from embryonic and tumorigenic kidney cells of a human fetus. This cell line expresses vitronectin receptors composed of the integrin beta-1 subunit as well as the vitronectin receptor alpha-v subunit and could be useful for testing efficacy of virucide. This cell line also makes an excellent transfection host. The 293 cell line is a hypotriploid human cell line that exhibits epithelial morphology. The modal chromosome number of 64 occurs nearly in 30% of cells. 293 cells contain Adenovirus 5 DNA on the left end sequence of the viral genome. All other 293 types of cell lines are derivatives of this parent cell line. All of the daughter cells exhibit similar characteristics. The 293 cell line was derived from cancerous fetal kidney tissue and is a reliable host for transfection studies carried out for cancer research. Altogen Biosystems provides transfection kits with low cytotoxicity for the 293 cell line.

Data:
293 Cell Transfection Reagent

Figure 1. GAPD mRNA levels were quantified using real-time RT-PCR in the 293 cells transfected with siRNAs targeting GAPD or non-silencing siRNA. Forty-eight hours post-transfection, the cells were harvested and analyzed by real-time RT-PCR for GAPD mRNA expression levels. Data were normalized against the 18S rRNA signal. Control samples were either mock-transfected or untreated. Values are normalized to untreated sample. Data are means ± SD (n=5).

293-cells-transfection-protocol

Figure 2. Protein expression of GAPDH in 293 cells. DNA plasmid expressing GAPDH or siRNA targeting GAPDH were transfected into 293 cells following Altogen Biosystems transfection protocol. At 72 hours post-transfection the cells were analyzed by Western Blot for protein expression levels (normalized by total protein, 10 µg of total protein loaded per each well). Untreated cells used as a negative control.

Selected in vivo transfection product citations (ALTOGEN® IN VIVO Transfection Kits used in the following publications):

  • Nature. 2008 454(7203):523-7. Innate immunity induced by composition-dependent RIG-I …Saito et al [PDF]
  • Am J Pathology. 2010 177(4):1870-80. Role of ocular complement factor H in a murine model … Lyzogubov et al [PDF]
  • Nature Biotechnology. 2011 29(4):341-5. Delivery of siRNA to the mouse brain by … Alvarez-Erviti et al [PDF]
  • Cancer Research. 2011 71(15):5144-53. Inhibition of miR-193a expression by… Iliopoulos et al [PDF]
  • Hypertension. 2015 65(2):430-9. Neurokinin 3 receptor and phosphocholine transferase… Parchim et al [PDF]

Request a Quote for
293 Transfection Reagent

Altogen Biosystems:

Altogen Biosystems is a life sciences company that manufactures over 100 cell type specific and preoptimized transfection kits, elecroporation buffers, and targeted in vivo delivery kits and reagents. Advanced formulation of reagents and optimized transfection protocols provide highly efficient intracellular delivery of biomolecules (proteins, DNA, mRNA, shRNA and siRNA, and small molecule compounds). Read more about transfection technology at Altogen’s Transfection Resource.

Altogen Research Services:

Altogen Labs provides GLP-compliant contract research studies for pre-clinical research, IND applications, and drug development. Biology CRO services include: Xenograft models (30+), development of stable cell lines, ELISA assay development, cell-based and tissue targeted RNAi studies, safety pharm/tox assays, and other studies (visit AltogenLabs.com).

Volume Options:

  • 0.5 ml (Catalog #1151)
  • 1.5 ml (Catalog #1152)
  • 1.5 ml CRISPR (Catalog #2204)
  • 8.0 ml (Catalog #7014)
新闻动态
行业前沿
技术文章
最新产品