Deprecated: Required parameter $cat_id follows optional parameter $type in /www/wwwroot/ebimall.com/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /www/wwwroot/ebimall.com/systems/hlb.php on line 3505
Kapa biosystems/KAPA Library Amplification Kits/KK2702/250 x 50 µL reactions188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线

Kapa biosystems/KAPA Library Amplification Kits/KK2702/250 x 50 µL reactions

Description:

Real-timePCRlibraryamplification,withfluorescentstandards

KAPALibraryAmplificationKits

ThegoldstandardforNGSlibraryamplification.

KAPALibraryAmplificationKitscontainKAPAHiFiDNAPolymerase,anovelenzymeengineeredforultra-highfidelityandrobustnessusingKapa’sdirectedevolutiontechnologyplatform.

KAPAHiFihasbecometheenzymeofchoiceforNGSlibraryamplificationduetoitsabilitytoamplifycomplexDNApopulationswithhighfidelity,highefficiency,decreasedPCRduplicationratesandverylowbias.*ThisresultsinlowerduplicationratesandimprovedcoverageofGC-andATrichregions,promoters,lowcomplexityandotherchallengingregionsinallNGSlibraryconstructionworkflowsrequiringlibraryamplification.

Inadditiontothestandardlibraryamplificationformulation,KAPAHiFiisavailableinauniquereal-timeformulation,forapplicationsthatdemandprecisecontroloverlibraryamplification.Auracil-tolerantvariant,KAPAHiFiUracil+isalsoavailableforthehigh-efficiency,high-fidelity,low-biasamplificationoflibrariesconstructedfrombisulfite-treatedDNA.

KAPALibraryAmplificationKitsforIllumina® platformsnowalsoincludeanoptimallyformulatedLibraryAmplificationPrimerMix.

*Dataonfile.

ForResearchUseOnly.Notforuseindiagnosticprocedures.

ProductHighlights

Achievethelowestamplificationbiasandduplicationrates

  • Loweramplificationbiasresultinimprovedrepresentationofalllibraryfragmentsandsequenceregions
  • High-efficiencyamplificationleadstofeweramplificationcyclesandlowerPCRduplicates
  • Lessadditionalnext-generationorSangersequencingneededtocompletegenomes
The first exons of many genes have a high GC content, and are therefore difficult to amplify. Regions of these exons are therefore typically underrepresented in whole exome sequence data. Pre-capture amplification with the evolved, low-bias KAPA HiFi DNA Polymerase results in significantly improved coverage of GC- and AT-rich regions, and other sequence elements that are difficult to amplify. Data courtesy of The Broad Institute. Data on file.

ImprovecoverageofGC-andAT-richregions

  • LoweramplificationbiasimprovescoverageuniformityofGC-andAT-richregions,promoters,lowcomplexityandotherchallengingregions
  • ImprovedoverallcoverageandcoverageuniformityobservedonbothIllumina andIonTorrent™ sequencingplatforms
Real-time, high fidelity amplification of multiple libraries with the KAPA Real-Time Library Amplification Kit. Twenty libraries, spanning a ~64-fold concentration range (equivalent to 6 cycles), were simultaneously amplified and terminated after 14 cycles. Fourteen of the twenty libraries fall within the targeted amplification range (the fluorescence range defined by the Real-Time Amplification Standards 1¬–3). The remaining six libraries could either be used as is, noting that they may be outside the optimal concentration range, or they could be re-amplified individually or in high- or low-concentration groups. Data on file.

Exerciseprecisecontroloverlibraryamplification

  • KAPAReal-TimeAmplificationKitsallowforlibraryamplificationtobeobservedinrealtime
  • Terminateamplificationattheoptimalpointforindividualsamples
  • Optimizelibraryamplificationparametersforhigherthroughputworkflows
Error rates of Taq DNA polymerase and polymerases typically used in NGS library amplification. The error rates of proofreading DNA polymerases such as Q5 (New England Biolabs), Phusion (Thermo Scientific) and the evolved KAPA HiFi DNA Polymerase is 50 – 100 times lower than that of Taq. The error rate of KAPA HiFi was confirmed by deep sequencing on the 454 platform, and is 1 error per 3.54 x 106 nucleotides incorporated. Data on file.

AmplifyNGSlibrarieswithindustry-leadingfidelity

  • KAPAHiFiwasengineeredusingdirectedevolutiontohaveenhancedproofreading(3′-5′exonuclease)activity
  • Industry-leadingfidelityconfirmedby454sequencing

Applications:

Applications
  • AmplificationofIllumina libraries(DNAandRNAsequencing)
  • Real-timeamplificationoflibrariespreparedfromlowinput,ChIPDNAandotherprecioussamples
  • Pre-andpost-captureamplificationintargetedcaptureworkflows

KitSpecificationsandContents/Storage:

KitSpecificationsandContents/Storage

Kitscanbestoredforupto12months at-20˚C.

KitsincludeKAPAHiFiHotStartReadyMix(2X),aconvenientPCRmastermixcontainingKAPAHiFiHotStartDNAPolymerase,KAPAdNTPs,reactionbuffer,andMgCl2atafinalconcentrationof2.5mM.Kitswithprimersarealsoavailable.

Kitsforreal-timelibraryamplificationincludeareal-timeversionoftheKAPAHiFiHotStartReadyMix,aswellasfluorescentstandardstomonitorlibraryamplification.

Components

LAK_Component Chart

Specifications

Spec
Description
CompatiblePlatform
IlluminaHiSeq,MiSeq,NextSeq,andGAIIx
LibraryType
DNA,RNA,andbisulfite-treatedDNA
StartingMaterial
AnyNGSlibrarythatrequiresamplification
SequencingApplications
WholeGenomeSequencingWholeExomeSequencingTargetedSequencing(custompanels)RNA-SeqChIP-SeqAmpliconSequencing

新闻动态
行业前沿
技术文章
最新产品

188进口试剂采购网 www.188bio.cn -中国试剂网,试剂网,化学试剂网,国药试剂,抗体公司,试剂公司,试剂盒公司,苏州试剂公司,北京化学试剂公司,天津化学试剂,试剂商城,试剂代理,流式抗体 细胞库查询 sitemap