Deprecated: Creation of dynamic property cls_session::$session_data_table is deprecated in /www/sites/www.188bio.com/index/systems/cls_session.php on line 49
asuragen/AmplideX® PCR/CE <em>SMN1</em> Kit/50/A00001188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

asuragen/AmplideX® PCR/CE SMN1 Kit/50/A00001

AmplideX® PCR/CE SMN1 Kit

The AmplideX PCR/CE SMN1 Kit* provides a rapid, robust, and reliable method for the quantification of SMN1 exon 7 copy number from whole blood and buccal samples.  With its streamlined PCR/CE workflow, rapid turnaround time, and automated results reporting software, the assay provides a simple and scalable SMN1 solution for all laboratories.

Features & Benefits

AmplideX technology has become widely established for the detection and quantification of repeat expansions in a number of genes, including FMR1, C9orf72, and DMPK.  With the AmplideX PCR/CE SMN1 Kit, this approach is applied to copy number resolution, allowing SMN1 exon 7 copy number to be estimated in under four hours using readily available laboratory equipment.

Reduced Complexity
  • Similar workflow to the AmplideX FMR1 kit* eases implementation and testing
  • Scalable design allows for high-throughput testing
  • Automated analysis objectively reports copy number
Optimized Workflow
  • A simplified workflow compared to alternative methods
  • Fully kitted solutions with fewer QC and pipetting steps
  • DNA to data in under four hours with only 45 minutes of hands-on-time
Quality Performance
  • Ability to differentiate between 0, 1, 2, 3 and > 3 copies
  • Robust, reliable results with non-overlapping ratios for each copy number output
  • Concordance with previously characterized samples

Download Brochure

*For Research Use Only. Not for use in Diagnostic procedures.CE-IVD for US Export Only.

Analytical Characteristics

Analytical characteristics of AmplideX PCR/CE SMN1 Kit:

  • Excellent concordance with previously characterized clinical samples (Figure 1)
  • Consistent results compared to other commercially available methods (Figure 2)
  • Automated results reporting via AmplideX Reporter software (Figure 3)

Figure 1. Excellent concordance with previously characterized clinical samples.

Figure 2: Consistent results compared to other commercially available methods.

Figure 3: Automated results reporting via AmplideX Reporter software.

Figure 4: Workflow for the AmplideX PCR/CE SMN1 Kit

Ordering Information

Product NameNumber of ReactionsCatalog Number
AmplideX® PCR/CE SMN1 Kit (RUO)9649660
AmplideX® PCR/CE SMN1/2 Kit (RUO)50A00001

T 1-877-777-1874; 512-681-5200 F 512-681-5202 E orders@asuragen.com

View Sales Contacts

AmplideX® PCR/CE SMN1 Kit

The AmplideX PCR/CE SMN1 Kit* provides a rapid, robust, and reliable method for the quantification of SMN1 exon 7 copy number from whole blood and buccal samples.  With its streamlined PCR/CE workflow, rapid turnaround time, and automated results reporting software, the assay provides a simple and scalable SMN1 solution for all laboratories.

Analytical Characteristics

Ordering Information

Product NameNumber of ReactionsCatalog Number
AmplideX® PCR/CE SMN1 Kit (RUO)9649660
AmplideX® PCR/CE SMN1/2 Kit (RUO)50A00001

T 1-877-777-1874; 512-681-5200 F 512-681-5202 E orders@asuragen.com

View Sales Contacts
新闻动态
行业前沿
技术文章
最新产品