Deprecated: Required parameter $cat_id follows optional parameter $type in /www/wwwroot/ebimall.com/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /www/wwwroot/ebimall.com/systems/hlb.php on line 3505
LI-COR/IRDye® QC-1 NHS Ester/[{size: 0.5 mg, price_type: Default, price_USD: 130.0, price_GBP: 235.0, long_desc: <p>It is a water-soluble, monoreactive NHS ester dye, which allows it to be used to<a class=myaqpyqbezh title=Click to Conti188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

LI-COR/IRDye® QC-1 NHS Ester/[{size: 0.5 mg, price_type: Default, price_USD: 130.0, price_GBP: 235.0, long_desc:

It is a water-soluble, monoreactive NHS ester dye, which allows it to be used to

IRDye QC-1 is the first non-fluorescent (dark) quencher compatible with a wide range of visible and near-infrared fluorophores (~500-800 nm). It has the widest available quenching range, so you do not need to carefully match the donor"s fluorescence spectrum with the acceptor"s absorbance. IRDye QC-1 quenches common fluorophores with >97% efficiency1.

IRDye QC-1 stokes shift and wavelength
Energy that is transferred from the donor (Dem) can be emitted at the acceptor"s wavelength (Aem), quenching fluorescence.

For more information, see “Spectral Overlap of IRDye QC-1 Absorption with Common Donor Fluorophores” below.

IRDye QC-1 NHS ester can be used for FRET (fluorescence resonance energy transfer) applications such as protease assays. Recently, it has been paired with IRDye 800CW in optoacoustic studies.

IRDye Infrared Dyes Overview

Dye Structure

IRDye QC-1 NHS Ester structure

Properties

  • Chemical Formula: C53H62C|N4Na3O16S4
  • Molecular Weight: 1243.75 g/mol
  • Exact Mass: 1242.24

Absorption Spectrum

SolventExt. Coeff. (M-1cm-1)Absorption Maxima
1X PBS96,000737 nm
Water98,000788 nm

Absorption Spectrum in 1X PBS

IRDye® QC-1 Absorption Spectrum in PBS

Absorption Spectrum in Methanol

IRDye® QC-1 Absorption Spectrum in Methanol

Spectral Overlap of IRDye QC-1 Absorption with Common Donor Fluorophores

IRDye QC-1 spectral overlap with common donor fluorophores
Normalized emission spectra for several common donor fluorophores, and the absorption spectrum of IRDye QC-1. All are quenched by IRDye QC-1 with >97% efficiency. Reprinted with permission from Analytical Biochemistry 388 (2009) 220-28.
IRDye QC-1 list of fluorophores
List of fluorophores and spectrally compatible quenchers (shaded box = compatible). Almost all of these common fluorophores are spectrally compatible with IRDye QC-1. No other quencher spans this wide range or is compatible with wavelengths near 800 nm. Reprinted with permission from Analytical Biochemistry 388 (2009) 220-28.

Reference

  1. Peng, X et al. A nonfluorescent, broad range quencher dye for Fõrster resonance energy transfer assays. Anal Biochem. 388(2):220-28 (2009).

To discuss purchase quantities over 1 gram or commercial development rights using IRDye infrared dyes, please contact Business Development.