Quidel/Lyra Direct HSV/VZV Assay/M102/96 tests

Description:

AssayKit

Features&Benefits:

TheLyraDirectHSV1+2/VZVAssayisamultiplexinvitrotestthatdetectsanddifferentiates Herpessimplexvirustype1,Herpessimplexvirustype2,andVaricella-zostervirusnucleicacidsisolatedandpurifiedfromcutaneousormucocutaneousswabspecimensobtainedfromsymptomaticpatients.

Amultiplexreal-timePCRreactioniscarriedoutunderoptimizedconditionsinasingletubegeneratingampliconsforHSV-1,HSV-2,VZV,andtheProcessControl(PRC).IdentificationofHSV-1,HSV-2,VZV,andthePRCoccursbytheuseoftarget-specificprimersandfluorescent-labeledprobesthathybridizetoconservedregionsinthegenomesofHSV-1,HSV-2,VZVandthePRC.

TheLyraDirectHSV1+2/VZVAssayhasone-stepreagentset-upandathree-stepsampleprep.Testresultsareavailableinlessthan70minutes.TheLyraDirectHSV1+2/VZV AssayisavailableforuseonAppliedBiosystems®7500FastDx,QuantStudio™DxReal-TimePCRInstrument,andCepheid®SmartCycler®II.

TheLyraDirectHSV1+2/VZVAssayisoneinagrowingmenuofPCRtestsandisusedasanaidinthedifferentialdiagnosisofHerpessimplexvirus1and2(HSV-1andHSV-2)andVaricella-zostervirus(VZV)alsoknownasHumanherpesvirus3.VZVisthecausativeagentforchickenpoxandshingles.


FeatureBenefit
One-stepreagentset-up

RehydrationsolutionissimplyaddedtothelyophilizedMasterMix

Speed

Resultsinlessthan60minutes

Easytraining

Simplifiedanduniformworkflowwithstandardpipettingvolumes

Refrigeratedstorage

Nofreezerneeded.2°Cto8°Cstorage

Longshelflife

2yearsfromdateofmanufacture

Roomtemperaturesetup

Noiceorcoolingblockrequired

FlexIBLe96-testformat

Kitincludesvialsof12x8MasterMix,RehydrationSolutionandliquidProcessControls.Samplepreparationkitincludesallconsumables

ProductSpecifications:

ProductSpecNameProductSpecData
Sampletype

Cutaneousormucocutaneousswabspecimens

Timetoresults

Lessthan60minutes

Reagentstorageconditions

2°Cto8°C

Controlsstorageconditions

2°Cto8°C

Samplevolumeneededforextraction

100µL

Purifiednucleicacidvolumeneededtotesting

5µL

Sensitivity*

Cutaneous:HSV-1100.0%,HSV-297.1%,VZV96.3%;Mucocutaneous:HSV-195.1%,HSV-297.9%,VZV100.0%

Specificity*

Cutaneous:HSV-198.8%,HSV-296.7%,VZV96.4%;Mucocutaneous:HSV-198.2%,HSV-297.1%,VZV99.3%

Shelflife

24months

*DataforAppliedBiosystems™7500FastDx. RefertoPackageInsertforadditionalperformanceclaims.