METTLER/Solvent Manager/51105652/1 Ea

SolventManager

TheSolventManagerisadeviceforthehandlingofliquidsagainstthecontactoftheuserwithchemicals.
Specifications - SolventManager
MaterialNumber(s)51105652

Description
V30 Solvent ManagerSafehandlingofKarlFischerchemicalswiththeSolventManager

ContactwithKarlFischerreagentsshouldalwaysbeavoided.TheSolventManagertakescareoffilling,purgingandexchangeofthereagents.ItisfullycontrolledbythetitratorwhichoffersOneClick™accesstoalltasks;fullsecurityagainstoverflowsisguaranteedbythelevelsensorinthewastebottle.

Solvent Manager for the general TitrationSolventManagerforthegeneralTitration

TheintegrationofthedrainfunctionintothemethodallowsaspirationofthesampleaftertheTitrationwithoutanyuserintervention,savingtheoperatortime. 
TheSolventManagercanalsobeusedtogetherwiththeRondolinoandRondosamplechangerstoemptythebeakersafteranalysis,preventingthelaboratoryfromexposuretosolvents.

Solvent/ReagentControl(V30/C30):
monitoringofimportantparametersanddirectexchangeofthechemicals.

Thetitrationcellisalwaysingoodcondition,asSolventorReagentControlmonitorsthreedifferentparametersandreplacesthesolventwhennecessaryinOneClick™.TheSolventManageralsoempties,fillsorreplacesthesolventwheneverrequiredandkeepstheuserfullyprotected.

CompactVolumetricKFTitrators:
Simpleandsecuresolventmonitoring

Thesolventneedstobereplacedregularlyinordertoguaranteeconsistentlycorrectresults.TheSolventControlsupportstheuserbymonitoringthreedifferentparameters.Forexample,ifonlytensamplesaresolublein100mLofthesolventtheSolventControlremindstheuserafter10samplestoexchangethesolventandoffersthiswithaOneClick™taskbutton.EvenwhenaninstrumentisrunningonStandbytheSolventControlisactiveandautomaticallystartsconditioningofthefreshsolventafterexchange.Withminoruserinteractionthesystemisalwayskeptinoptimumconditionreadytoensureaquick,accurateresultwheneverrequired.

CompactCoulometers:
AlwaysingoodshapethankstoReagentControl

ThereagentsplayanimportantroleinthecoulometricKarlFischertitration.TheReagentControlkeepsaneyeonthreeparameterssothatoncethemaximumcapacityisreachedtheuserispromptedtoreplacethereagents.TheControloffersthepossibilitytostarttheexchangewithOneClick™evenwhenamethodisrunningonStandbyandthefreshreagentwillimmediatelystartbeingconditioned.Contactwithanyofthereagentsisavoidedandtheuseralwayshasanoptimalsystem,readytouseandpreparedtogeneratecorrect,repeatableresults.

OrderInfo:

ForKarlFischerCompactline:

51105600 SolventManagerset 

Note:TheSampleManagerisincludedinthestandarddeliveryoftheCompactKFtitrators!

ForTitrationExcellence(T70/T90forKarlFischer)

51105605 KFKit(IncludingSolventManager,titrationstand,vessel,sensor,tubesandallaccessories)

TitrationExcellence(T50/T70/T90)andCompactTitratorG20forgeneraltitration
51105652SolventManagerKit(includesSolventManagerSet,andtheneededaccessoriesfortheuseoftheSolventMangerinthegeneraltitration.)