产品资料

CHROMOGENIX/Factor VIII/1 vial/82 2585 63

About usIProductsITechnology
Package InsertsIMSDS
  • Products
    • Haemostasis Kits
      • APC-R
      • APCR-V
      • Protein C - Protein S
      • Factor VII
      • Factor VIII
        • COAMATIC®...
        • COATEST® SP...
        • COATEST®...
      • Heparin
    • Calibrators & Controls
    • Bio-Reagents
    • Chromogenic Substrates

Co-lyophilisation of reagents for convenient handling. Reliable tool for haemophilia classification. No interference from heparin levels up to 1.5 IU/ml.

The Factor VIII kits have two measuring ranges.Validated and documented protocols for automated instruments. All the Factor VIII kits can be used for the potency estimation of Factor VIII according to the European Pharmacopoeia requirements.

COAMATIC® FACTOR VIII

A chromogenic kit for the determination of factor VIII activity in human plasma, blood fractions and purified preparations. Fulfills the requirements of the European Pharmacopoeia for factor VIII concentrate testing.

Measurement Principle

82 2585 63

Reagents and their stability when opened

S-2765+I-2581
1 vial
1 month
2-8°C
Factor reagent
2 vials
1 day
2-8°C
1 month
-70°C
Buffer
1 vial
1 month
2-8°C

Determinations

Test tube method
30
Microplate method
120
Automated methods
up to 100

Part Number: 82 2585 63

COATEST® SP FVIII

The classic chromogenic kit for the determination of factor VIII activity in human plasma, blood fractions and purified preparations.

Measurement Principle

82 2585 63

Reagents and their stability when opened

S-2765+I-2581
1 vial
3 months
2-8°C
FIXa+FX
1 vial
12 hours
2-8°C
3 months
-20°C
CaCl2
1 vial
exp. date
2-8°C
Buffer
1 vial
3 months
2-8°C
Phospholipid
1 vial
3 months
2-8°C

Determinations

Test tube method
60
Microplate method
240
Automated methods
up to 200

Part Number: 82 4086 63

COATEST® SP4 FVIII

A chromogenic kit for the determination of factor VIII activity in human plasma, blood fractions and purified preparations. Suitable for low volume testing.

Measurement Principle

82 2585 63

Reagents and their stability when opened

S-2765+I-2581
1 vial
3 months
2-8°C
FIXa+FX
1 vial
12 hours
2-8°C
3 months
-20°C
CaCl2
1 vial
exp. date
2-8°C
Buffer
1 vial
3 months
2-8°C
Phospholipid
1 vial
3 months
2-8°C

Determinations

Test tube method
4x20
Microplate method
240
Automated methods
up to 200

Part Number: 82 4094 63