Deprecated: Required parameter $cat_id follows optional parameter $type in /www/wwwroot/ebimall.com/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /www/wwwroot/ebimall.com/systems/hlb.php on line 3505
devatal/Recombinant Human Rantes (CCL5)/5ug/4133188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

devatal/Recombinant Human Rantes (CCL5)/5ug/4133

Recombinant Human Rantes (CCL5)

Catalog #

4133

Price:

From $50.00 to $3,000.00
5ug - $50
20ug - $120
1000ug - $3,000

CERTIFICATE OF ANALYSIS AND DATA SHEET

4133: Recombinant Human Rantes (CCL5)

Description:Recombinant Human Rantes produced in E.Coli is a single, non-glycosylated polypeptide chain containing 68 amino acids and having a molecular mass of 7809.2 Dalton. The rHuRantes is purified by proprietary chromatographic techniques.

Source:Escherichia Coli.

Formulation:Lyophilized from a concentrated (1mg/ml) solution in water containing no additives. Solubility:It is recommended to reconstitute the lyophilized rHuRantes in sterile 18MΩ-cm H2O not less than 100µg/ml, which can then be further diluted to other aqueous solutions.

Stability:Lyophilized rHuRantes although stable at room temperature for 3 weeks, should be stored desiccated below -18C. Upon reconstitution rHuRantes should be stored at 4C between 2-7 days and for future use below -18C. For long term storage it is recommended to add a carrier protein (0.1% HSA or BSA). Please prevent freeze-thaw cycles.

Purity:Greater than 98.0% as determined by: (a) Analysis by RP-HPLC. (b) Anion-exchange FPLC. (c) Analysis by reducing and non-reducing SDS-PAGE Silver Stained gel

Amino acid sequence: The sequence of the first five N-terminal amino acids was determined and was found to be Ser-Pro-Tyr-Ser-Ser.

Dimers and aggregates:Less than 1% as determined by silver-stained SDS-PAGE gel analysis.

Biological Activity:Fully biologically active when compared to standard. The activity is determined by the chemoattract of human blood monocytes at a concentration between 1-10ng/ml.

Endotoxin:Less than 0.1 ng/µg (IEU/µg) of rHuRantes.

Protein content:Protein quantitation was carried out by two independent methods:1. UV spectroscopy at 280 nm.2. Analysis by RP-HPLC, using a standard solution of Eotaxin as a Reference Standard.

DevaTal, Inc, 644 Newkirk Ave, Hamilton NJ 08610 Phone: 609-586-1575, Fax: 609-586-6892
FOR RESEARCH USE ONLY

Share this product

新闻动态
行业前沿
技术文章
最新产品