Deprecated: Required parameter $cat_id follows optional parameter $type in /www/wwwroot/ebimall.com/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /www/wwwroot/ebimall.com/systems/hlb.php on line 3505
Athens Research/Cambio - Excellence in Molecular Biology/6 strips, 8 vials each/57-2102188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线
产品资料

Athens Research/Cambio - Excellence in Molecular Biology/6 strips, 8 vials each/57-2102

PCR

PCR : PCR Products

The FailSafe™ PCR system for templates up to 20kb long, high GC content (up to 85% G+C), & Multiplex PCR

  • Catalogue
  • Description

PCR cycler Check™ and qPCR cycler Check™

Thermal Cycler Validation Kits for Traditional and qPCR Thermal Cyclers

Minerva Biolabs

Catalogue No.DescriptionPack SizePriceQty
  • Change to:
  • €
57-2102PCR Cycler Check™ Advance6 strips, 8 vials each£197.00QuantityAdd to Order
57-2103PCR Cycler Check™ OneStep100 reactions£197.00QuantityAdd to Order
57-2202qPCR Cycler check™100 Reactions£495.00QuantityAdd to Order

PCR cycler Check™ and qPCR cycler Check™

Thermal Cycler Validation Kits for Traditional and qPCR Thermal Cyclers

Minerva Biolabs

PCR Cycler Check™

Validation tools for conventional PCR cycler

Validation tools for testing PCR thermal cyclers according to legal requirements

ISO 17025, EN 45001, ISO 13485, ISO/TS 20836:2007, GLP, GMP, IQ/OQ/PQ, and others.

Cycler Check Kits

The PCR Cycler Check Kits are available for both conventional endpoint PCR and real-time PCR (qPCR) cyclers.

False negative PCR results are highly critical and might be caused by a defect PCR cycler. Verification of the correct temperature control of the used equipment is usually a stressful issue. To comply with quality management systems is not easy to fulfill for PCR cyclers.

Principle

The PCR Cycler Check Kits provide temperature sensitive PCR reactions to monitor an upper and lower temperature range in one run. The primer/ probe sequences in the PCR Cycler Check Kits were designed to react extremely sensitive to incorrect temperature control, temperature homogeneity, precision and timing. Amplification will completely drop out at temperature differences of more than 2°C. The cycler performance is tested at standard PCR settings to reflect most user’s applications. In addition, the pre-adjusted target concentrations are only amplified at high PCR efficiencies as an additional indicator for accurate temperature control of the thermal cycler.

Benefits

• No extra equipment, instrument or software needed. • Applicable with any block PCR cycler or qPCR cycler used in a research or industrial quality assurance lab for the reliability testing of instrument performance and reliability. • In the qPCR Thermal Cycler Validiation Kit the probes of each amplification system are labeled with different fluorescent dyes (FAM™ and ROX™) to allow individual evaluation of each temperature range. • Includes all you need: Freeze-dried primer/probe sets, polymerase, nucleotides and rehydration buffer

qPCR Cycler Check™

Validation tools for conventional and qPCR cycler

Validation tools for testing PCR thermal cyclers according to legal requirements ISO 17025, EN 45001, ISO 13485, ISO/TS 20836:2007, GLP, GMP, IQ/OQ/PQ, …

Cycler Check Kits

The PCR Cycler Check Kits are available for both conventional endpoint PCR and real-time PCR (qPCR) cyclers.

False negative PCR results are highly critical and might be caused by a defect PCR cycler. Verification of the correct temperature control of the used equipment is usually a stressful issue. To comply with quality management systems is not easy to fulfill for PCR cyclers.

Principle

The PCR Cycler Check Kits provide temperature sensitive PCR reactions to monitor an upper and lower temperature range in one run. The primer/ probe sequences in the PCR Cycler Check Kits were designed to react extremely sensitive to incorrect temperature control, temperature homogeneity, precision and timing. Amplification will completely drop out at temperature differences of more than 2°C. The cycler performance is tested at standard PCR settings to reflect most user’s applications. In addition, the pre-adjusted target concentrations are only amplified at high PCR efficiencies as an additional indicator for accurate temperature control of the thermal cycler.

Benefits

• No extra equipment, instrument or software needed. • Applicable with any block PCR cycler or qPCR cycler used in a research or industrial quality assurance lab for the reliability testing of instrument performance and reliability. • In the qPCR Thermal Cycler Validiation Kit the probes of each amplification system are labeled with different fluorescent dyes (FAM™ and ROX™) to allow individual evaluation of each temperature range. • Includes all you need: Freeze-dried primer/probe sets, polymerase, nucleotides and rehydration buffer.

If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200