EXBIO/Annexin V FITC/100 tests/EXB0024

Product details
Images
Application
FC (QC tested)
Description
Annexin V FITC is intended for detection of early apoptotic cells by flow cytometry.
Contents
Annexin V FITC - 1 vial (0.5 ml / 2.5 ml) of Ready-to-use solution. No reconstitution is necessary. Reagent is provided in stabilizing phosphate buffered saline (PBS) solution containing 15mM sodium azide. Sufficient for 100 / 500 tests.
Preparation
Bacterially expressed and fluorescently labelled annexin V was diluted in stabilizing buffer. The reagent is free of unconjugated fluorochrome.
Formulation
Stabilizing phosphate buffered saline (PBS) solution containing 15mM sodium azide
Storage and handling
Store in the dark at 2-8°C. Do not freeze. Avoid prolonged exposure to light. Do not use after expiration date stamped on vial label.
Exbio licence note
Unless indicated otherwise, all products are For Research Use Only and not for diagnostic use. In vivo diagnostic or therapeutic applications are strictly forbidden. Products shall not be used for resale or transfer to third parties either as a stand-alone product or as a manufacture component of another product without written consent of EXBIO Praha, a.s. EXBIO Praha, a.s. will not be held responsible for patent infringement or any other violations of intellectual property rights that may occur with the use of the products. Orders for all products are accepted subject to the Term and Conditions available at www.exbio.cz. EXBIO, EXBIO Logo, and all other trademarks are property of EXBIO Praha, a.s. © 2019 EXBIO Praha, a.s. All rights reserved.
EXB0024_FC_Dot-plot
Flow cytometry multicolor surface staining of camptothecin induced apoptotic Jurkat cells stained using Annexin V FITC (5 μl reagent per million cells in 100 μl of cell suspension) and Hoechst 34580 viability stain.
EXB0024_FC_Histogram
Separation of Annexin positive Hoechst 34580 positive events (red-filled) from Annexin negative Hoechst 34580 negative events (black-dashed) in flow cytometry analysis (surface staining) of camptothecin induced apoptotic Jurkat cells stained using Annexin V FITC (5 μl reagent per million cells in 100 μl of cell suspension).
EXB0024_FC_Profil Značení
Flow cytometry surface staining pattern of camptothecin induced apoptotic Jurkat cells stained using Annexin V FITC (5 μl reagent per million cells in 100 μl of cell suspension).
EXB0024 FC
Flow cytometry staining of apoptotic JURKAT cells with annexin V FITC and 7-AAD.