Deprecated: Required parameter $cat_id follows optional parameter $type in /www/wwwroot/ebimall.com/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /www/wwwroot/ebimall.com/systems/hlb.php on line 3505
GenWay/Rat GST Yb1 (mu) ELISA/GWB374Z44/96 well188bio精品生物—专注于实验室精品爆款的电商平台 - 蚂蚁淘旗下精选188款生物医学科研用品
您好,欢迎您进入188进口试剂采购网网站! 服务热线:4000-520-616
蚂蚁淘商城 | 现货促销 | 科研狗 | 生物在线

GenWay/Rat GST Yb1 (mu) ELISA/GWB374Z44/96 well

AdditionalInformation:


新闻动态
行业前沿
技术文章
最新产品
NameRatGSTYb1(mu)ELISA
RelatedProductNamesGlutathioneS-transferaseMu1,GST3-3,GSTM1-1,GlutathioneS-transferaseYb-1,GSTYb1,Gstm1,RatGlutathioneS-TransferaseYb1(GSTYb1)ELISAKit
ProteinNameGSTMu(Yb1)
SpeciesReactivityRat
AssayInfoAssayMethodology:QuantitativeSandwichELISA
Sensitivity1.025ng/ml
KitRange3.125ng/ml-100ng/ml
HomologyRat
StandardRangeReferToManual
SampleTypeSerum,plasmaandotherBIOLOGicalfluids
Specimen/VolumesReferToManual
SwissProtNumberP04905(GSTM1_RAT)
ApplicationsELISA
FormatELISAKit
ReconstitutionandStorage
1.DILUENT
The5XDiluentConcentrateisstableuntiltheexpira-tiondate.The1Xworkingsolutionisstableforatleastoneweekfromthedateofpreparation.Bothsolutionsshouldbestoredat4-8C.
2.WASHSOLUTION
The20XWashSolutionConcentrateisstableuntiltheexpira¬tiondate.The1Xworkingsolutionisstableforatleastoneweekfromthedateofpreparation.Bothsolutionscanbestoredatroomtemperature(1625C)orat4-8C.
3.ENZYME-ANTIBODYCONJUGATE
UndilutedhorserADIshperoxidaseanti-GSTYb1conjugateshouldbestoredat4-8Canddilutedimmediatelypriortouse.Theworkingconjugatesolutionisstableforupto1hourwhenstoredinthedark.
4.CHROMOGEN-SUBSTRATESOLUTION
TheSubstrateSolutionshouldbestoredat4-8Candisstableuntiltheexpirationdate.
5.STOPSOLUTION
TheStopSolutionshouldbestoredat4-8Candisstableuntiltheexpirationdate.
6.ANTI-RATGSTYb1ELISAMICROPLATE
Anti-RatGSTYb1coatedwellsarestableuntiltheexpirationdate,andshouldbestoredat4-8Cinsealedfoilpouchwithdesiccantpack.
7.RATGSTYb1CALIBRATOR
ShortTermStorage:theun-reconstitutedcalibratorisstableuntiltheexpirationdate.Theworkingstandardsolutionsshouldbepreparedimmediatelypriortouse.
ReactivityRat
KitSize96well
KitPrincipleGenWayBiotechGSTMu(Yb1)ELISAKit(Rat)(GWB-374Z44)isbasedonstandardsandwichenzyme-linkedimmuno-sorbentassaytechnology.AnantibodyforGSTMu(Yb1)hasbeenpre-coatedontoa96-wellplate(12x8WellStrips).Standardsortestsamplesareaddedtothewells,incubatedandwashedtoremoveunboundproteins.AnAnti-GSTMu(Yb1)-HRPconjugateddetectorantibodyisthenadded,incubatedandunboundconjugateiswashedaway.AnenzymaticreactionisproducedthroughtheadditionofTMBsubstratewhichiscatalyzedbyHRPgeneratingabluecolorproductthatchangestoyellowafteraddingacidicstopsolution.Thedensityofyellowcolorationreadbyabsorbanceat450nmisquantitativelyproportionaltotheamountofsampleGSTMu(Yb1)capturedinthewell.
KitComponent
ComponentAmount
Anti-RatglutathioneS-transferaseYb1_x000D_Microplate96Wells(12x8WellStrips)
20XDiluentConcentrate50mL
20XWashSolution50mL
100XEnzyme-AntibodyConjugate150uL
Chromogen-SubstrateSolution12mL
StopSolution12mL
RatglutathioneS-transferaseYb1_x000D_Calibrator1
KitDuration130Minutes
StorageRefertokitinstructionsforcomponentstorage
LeadTimeDomestic:within1weekdelivery International:1week
IntendedUseResearchUseOnly
AdditionalInformationINTENDEDUSE
TheGlutathioneS-TransferaseYb1(GSTYb1)testkitisahighlysensitivetwo-siteenzymelinkedimmunoassay(ELISA)formeasuringMuglutathioneS-transferase(GSTYb1,μGST)inbiologicalsamplesofrats.
::REAGENTS
1.DILUENT(RunningBuffer)
TheDiluentSolutionsuppliedisa5XConcentrateandmustbediluted1/5withdis¬tilledordeionizedwater(1partbufferconcentrate,4partsdH2O).

2.WASHSOLUTIONCONCENTRATE
TheWashSolutionsuppliedisa20XConcentrateandmustbediluted1/20withdis¬tilledordeionizedwater(1partbufferconcentrate,19partsdH2O).Crystalformationintheconcentrateisnotuncommonwhenstoragetemperaturesarelow.Warmingoftheconcentrateto3035Cbeforedilutioncandissolvecrystals.
.
3.ENZYME-ANTIBODYCONJUGATE
Calculatetherequiredamountofworkingconjugatesolutionforeachmicrotitreplateteststripbyadding10LEnzyme-AntibodyConjugateto990Lof1XDiluentforeachteststriptobeusedfortesting.Mixuniformly,butgently.Avoidfoaming.
4.CHROMOGEN-SUBSTRATESOLUTION
Readytouseassupplied.
5.STOPSOLUTION
Readytouseassupplied.
6.ANTI-RATGSTYb1ELISAMICROPLATE
Readytouseassupplied.UnsealMicrotiterPouchandremoveplatefrompouch.Removeallstripsandwellsthatwillnotbeusedintheassayandplacebackinpouchandre-sealalongwithdesiccant.
7.RATGSTYb1CALIBRATOR
Add0.5mLofdistilledorde-ionizedwatertotheRatGSTYb1andmixgentlyuntildissolved.Thecalibratorisnowataconcentrationof300ng/ml.RatGSTYb1standardsneedtobepreparedimmediatelypriortouse(seechartbelow).Mixwellbetweeneachstep.Avoidfoaming.